Product Description
TEADIT TF1570 Filled PTFE Gasket Sheet .
TEADIT TF1570 Filled PTFE Sheet .
TEADIT TF1570 PTFE Sheet filled with glass microspheres.
Tealon TF1570 | Blue
Tealon TF1570 is filled with glass microspheres and is suitable for aggressive chemical applications. It meets FDA conformance for service within food and pharmaceutical applications. TF1570 is the preferred material for fragile flanges, glass lined equipament or other applications that require higher compressibility.
Approvals: DVGW — TA-Luft — FDA
Tealon TF1580 | White
Tealon TF1580 (White) is filled with barium sulfate and is suitable for strong caustic fluids. It meets FDA conformance for service within food and pharmaceutical applications. 1580 can be used in a wide range of applications due to its vast resistance to most chemical products. It is compatible with strong acids along with strong caustics, making it the most diverse material within the Tealon family. With the white color of 1580, this material is also suitable for processes where contamination is not tolerated. Tealon 1580 meets and has been approved by BAM for oxygen service.
Approvals: DVGW — TA-Luft — FDA — BAM — Chlorine Institute
Tealon TF1590 | Fawn
Tealon TF1590 (Fawn) is filled with silica and meets a wide range of aplications. It is suitable for general service, strong acids and moderate caustic solutions. It meets FDA conformance for service within food and pharmaceutical applications. TF1590 has easily passed the Hot Compression Test with outstanding results.
Approvals: DVGW — TA-Luft — FDA — Chlorine Institute
Hot Compression Test
This performance test measures the behavior of rPTFE and PTFE gaskets in a real world environment. The chart below shows a comparison between conventionally skived PTFE and Tealon. The gaskets we tested simulated a real world application including thermo-cycling. The skived PTFE gasket showed a very high leak rate, losing 60% of its initial pressure by the end of the test.
The Tealon® gasket lost only 6% of its initial pressure by the end of the test and showed a leak 10 times less than that of the skived PTFE gasket. The pictures below, show the gaskets after the test and exhibit the dimensional stability of Tealon as compared to the noticeable creep of the skived PTFE gasket.
Thermo-Cycling Leak Test
Temperature cycles from 30º C to 200ºC, with seating stress of 5000psi and using a gasket thickness of 1/8".
Thermo-Cycling Leak Test Condition
Operating Parameters | TF1570 | TF1580 | TF1590 | |
---|---|---|---|---|
Temperature | -450 to 500 ºF (-268 to 260 ºC) | |||
Max. Pressure | 800 psig (55 bar) | 1200 psig (83 bar) | 1200 psig (83 bar) | |
Pressure x Temperature - psig x ºF (bar x ºC) | Thickness 1/16" | 350.000 (12.000) | ||
Thickness 1/8" | 250.000 (8.600) | |||
Sheet Size | 62"x62"* | |||
Availability | 1/32", 1/16", 3/32", 1/8", 1/4" | |||
Composition | PTFE with glass microspheres | PTFE with barium sulfate | PTFE with silica | |
* 59"x59" is available upon request. |
Physical Property | Type of Test | TF1570 | TF1580 | TF1590 |
---|---|---|---|---|
Color | Blue | White | Fawn | |
Sealability (ml/h) | ASTM F 37A | 0.12 | 0.04 | 0.20 |
Creep Relaxation (%) | ASTM F 38 | 40 | 24 | 18 |
Compressibility(%) | ASTM F 36J | 30-50 | 4-10 | 5-15 |
Recovery Min. (%) | ASTM F 36J | 30 | 40 | 40 |
Tensile Strength (MPa) | ASTM F 152 | 14 | 14 | 14 |
"m" and "y" factor | |||
---|---|---|---|
Product | Thickness (mm) | "m" | "y" (psi) |
TF1570 | 1.5 | 2 | 1,500 |
3 | 2 | 1,500 | |
TF1580 | 1.5 | 2 | 1,800 |
3 | 2 | 1,500 | |
TF1590 | 1.5 | 4.4 | 2,500 |
3 | 3.5 | 2,000 |
ASTM tests are based on 1/32" sheet thickness.
Sheet Size:
1500mm * 1500mm *1.5mm
1500mm * 1500mm *2.0mm
1500mm * 1500mm *3.0mm
Gaskets can be cut based on your drawing or sample.